Contax POWER MODULE SYSTEM Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Adaptadores e conversores de corrente Contax POWER MODULE SYSTEM. Comfort functions - GE Power Controls Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Redline Edition 2010

GE Consumer & IndustrialPower ProtectionRedline Edition 2010Modular DIN-rail devicesand residential enclosuresJust feel protectedGE imagination at

Página 2

RedlineD.9Contax RABCDEFGXPerformanceContax RCTX + R16Rated current (according to EN 60947-4-1)250VAC (1 & 2 pole) / 400VAC (3 & 4 pole) A 16N

Página 3 -

RedlineD.10Comfort functionsABCDEFGXImpulse switches and relays: maximum lamp loadsLamp Watts Pulsar S Pulsar S Contax RLamps type Power consumption

Página 4

RedlineD.11Contax RABCDEFGXContax R - RelaysNominal currentContact combinationCoil voltage ACCoil voltage DCNumber of ModulesCat. No. Ref. No. Pack.16

Página 5

RedlineD.12Comfort functionsABCDEFGXImpulse switchesPulsar SFunctionImpulse switches are electromechanically controlled switches used to control singl

Página 6 - MSC - Socket-outlets

RedlineD.13Pulsar SABCDEFGXPerformancePLS + PLS + C (4)PLS + 16 PLS + 32PLS + SA & SBPLS + PU 16 PLS + C 16 PLS + C 32Rated current (acc. to IEC 6

Página 7

RedlineD.14Comfort functionsABCDEFGXPulsar S - Impulse switchesNominal currentContact combinationCoil voltage ACCoil voltage DCNo. of ModulesCat. No.

Página 8 - Contax - Contactors

RedlineD.15Pulsar SABCDEFGXPulsar S - Impulse switchesNominal currentContact combinationCoil voltage ACCoil voltage DCNo. of ModulesCat. No. Ref. No.

Página 9

RedlineD.16Comfort functionsABCDEFGXStaircase switchesStandardsEN 60669-2-3 Pulsar TSFunctionPush-button operated single-shot timer, switching the pow

Página 10 - Performance

RedlineD.17Pulsar TSABCDEFGXPerformancePLTS + TD PLTS + M PLTS + DRated current (acc. IEC 669-2-3)A16 16 16Width (in number of DIN-modules)111Contacts

Página 11

RedlineD.18Comfort functionsABCDEFGXTime RelaysStandardsIEC 60669-2-3Pulsar TFunctionConditioning of incoming source to exact predictable output.Appli

Página 12 - Contax R - Relays

RedlineD.1ABCDEFGXCircuit ProtectionPeople ProtectionAdd-on DevicesComfort FunctionsBusbarsEnclosuresMCCB's Record PlusNumerical Index D.2 Switc

Página 13 - Dimensions

RedlineD.19Pulsar TABCDEFGXPulsar T - Time RelaysNominal currentContact combinationCoil voltage ACCoil voltage DCNo. of ModulesCat. No. Ref. No. Pack.

Página 14

RedlineD.20Comfort functionsABCDEFGXFunction Pre-programmed switching of all kinds of electrical devices.ClassicFeaturesVery easy programming by means

Página 15 - Pulsar S - Impulse switches

RedlineD.21ClassicABCDEFGXNET SYNCHRONISEDQUARTZ SYNCHRONISEDProgram1x24x21x24x21x24x47x24/37x24/21x24x21x24x21x24x47x24/37x24/31x24x2 + 1x24x21x24x2

Página 16

RedlineD.22Comfort functionsABCDEFGXDigital Time SwitchesFunctionPre-programmed switching of all kinds of electrical devices.StandardsBS EN-60730-1, B

Página 17

RedlineD.23GalaxABCDEFGXGalax - Digital time switches QUARTZ SYNCHRONISEDProgram No. of channelsSwitching capacityOperating voltageRunning reserveShor

Página 18 - Wiring diagram

RedlineD.24Comfort functionsABCDEFGX72 X 72 Classic and GalaxApplicationsGoing from the pre-programmed switching of lighting (car park, advertising s

Página 19

RedlineD.2572 x 72 Classic & GalaxABCDEFGXProgram1x241x247x247x24Program1x24/7x24No. of channels1CO1CO1CO1CONo. of channels1CONominalcurrent16A/25

Página 20 - Pulsar T - Time Relays

RedlineD.26Comfort functionsABCDEFGXStandardsVDE 0632, VDE 0633,BS EN 60669-1Galax LSSApplicationsControl of lighting in shop windows, offices, car pa

Página 21

RedlineD.27Galax LSSABCDEFGXProgram2 ... 500 lux2 ... 500 lux2 ... 2000 luxNo. of channels1NO2CO1NONominalcurrent16A/250V16A/250V16A/250VOperating vo

Página 22 - QUARTZ SYNCHRONISED

RedlineD.28Comfort functionsABCDEFGXFunctionReducing the voltage to a very low (safety) voltage used mainly as control-voltage in order to reduce the

Página 23

RedlineD.2Comfort functionsABCDEFGXApplicationsSwitching of lighting and heating in homes, shops, offices, warehouses, factories, hospitals, etc.Feat

Página 24 - Accessories

RedlineD.29Series TABCDEFGXOutput power5VA10VA15VA8VA 16VA30VA8VA15VA25VA40VA63VASecondary voltages8/12V8/12V8/12V12/24V12/24V12/24V8/12V12/24V12/24V1

Página 25

RedlineD.30Comfort functionsABCDEFGXFunctionMeasurement, visualisation andlogging of voltage, current,frequency, hours of operation,power, energy, cos

Página 26 - Example of application

RedlineD.31Series MTABCDEFGXScale300V500V-5A10A15A20A25A30A45 ... 65Hz230V/50Hz110V/50Hz24V/50HzAccuracy1.51.51.51.51.51.51.51.51.50.5---Number of ph

Página 27

RedlineD.32Comfort functionsABCDEFGXScale500V5A5A40 ... 80Hz9,99 W999 W5(30)A5(32)A5A5A63A63A5A5A (x/5A)Accuracy0.5% ± 2 dig0.5% ± 2 dig0.5% ± 2 dig0.

Página 28 - Accessories

RedlineD.33Series MTABCDEFGXScale40/5A50/5A60/5A80/5A100/5A150/5A200/5A250/5A300/5A400/5A500/5A600/5A800/5A1000/5A1200/5A1500/5A2000/5A40/5A50/5A60/5A

Página 29

RedlineD.34Comfort functionsABCDEFGXFunctionPriority relays offer the possibility to limit the energy consumptionin installations with a defined maxi

Página 30 - Series T - Transformers

RedlineD.35Series PRABCDEFGXRef. No. 666690666433Min. voltage value range-70-100%Functions Phases sequence Phases presence Phases sequence Phases

Página 31

RedlineD.36Comfort functionsABCDEFGXFunctionsProtection of an electrical installation and all electrical and electronic devices connected to this inst

Página 32

RedlineD.37SurgeGuardABCDEFGXParametersImpulse current (Iimp)This is the peak current that the SPD can withstand without failing. The wave-form of the

Página 33 - 4 tarifs

RedlineD.38Comfort functionsABCDEFGXSurgeGuard - Surge Arresters - Class I/BThe surge arresters have the capacity to divert excess energy for low volt

Página 34

RedlineD.3AsterABCDEFGXNominalcurrent40A/240V40A/415V40A/415V40A/415V63A/240V63A/415V63A/415V63A/415V80A/240V80A/415V80A/415V80A/415V100A/240V100A/415

Página 35 - Nominal Voltage Un 230V

RedlineD.39SurgeGuardABCDEFGXSurgeGuard - Surge Arresters - Class IIProtection for (DC)photovoltaic applicationsIimp In Up Up Up Umax No. Auxiliary No

Página 36 - Series PR - Priority relay

RedlineD.40Comfort functionsABCDEFGX21A1 A221141211A1 A214 12112ONOFFONOFFONOFF1A1 A2211422132114 2213 21141211A1 A214 12111424132114 2213 21122211211

Página 37

RedlineD.41PulsarABCDEFGXL21A1 A221141211A1 A214 12114231A1 A242314231A1 A2423124 1422 1221 11A1 A224 12142221 11642531A1 A262453168425731A1 A26824573

Página 38 - Parameters

RedlineD.42Comfort functionsABCDEFGXDimensional drawingsSwitches - AsterRotary switches - AsterPush-buttons - AsterSwitches with signal lamp - AsterIn

Página 39

RedlineD.43Dimensional drawingsABCDEFGXContactors Day and Night - ContaxContactors - Auxiliary contact Contactors - SpacerSocket-outlet - Series MSCCo

Página 40

RedlineD.44Comfort functionsABCDEFGX606217,6606417,696062606217,617,6917,6606435,2638617,6606417,6 35,2Dimensional drawingsImpulse switches - Pulsar S

Página 41 - Terminal capacity

RedlineD.45Dimensional drawingsABCDEFGX53 645°3545458,8638617,6618617,63817,6 17,6618617,6866117,6618617,6Dimmer - Pulsar TSSpacer - Pulsar STime-dela

Página 42 - Time relays - Pulsar T

RedlineD.46Comfort functionsABCDEFGXDimensional drawingsLight sensitive switch 1 module - Galax LSS Light sensitive switches 3 mod. - Galax LSSAnalogu

Página 43 - Dimensional drawings

RedlineD.47Dimensional drawingsABCDEFGXLight sensitive switch photocell incorporated Light sensitive switches - PhotocellSafety transformers - Series

Página 44 - Contactors - Contax

RedlineD.48Comfort functionsABCDEFGX43,855885559,460,91,5105854569,244901,517,59045725Dimensional drawingsAnalogue measurement instruments - Series MT

Página 45

RedlineD.4Comfort functionsABCDEFGXAsterFunction Status visualisation.ApplicationsMainly used to visualise the status of a (sub)part of the installati

Página 46 - SurgeGuard safety module

RedlineD.49Dimensional drawingsABCDEFGXCurrent transformer - Series MTSignal converter - Series MT Selector switch - Series MT81,55040 up to 80A500 an

Página 47

RedlineD.50Comfort functionsABCDEFGXDimensional drawingsSurge arresters - SurgeGuardTELE OV - Overvoltage protectionSA BLOCK, SA PHOT x 2 MODULES, SA

Página 48 - Buzzers and bells - Series T

50851GE POWER CONTROLS International Sales Nieuwevaart 51B-9000 Gent - BelgiumTel. +32/9 265 21 11Fax +32/9 265 28 90E-mail: [email protected] G

Página 49

RedlineD.5Aster and MSCABCDEFGXNominaloperating voltage-Nominaloperating voltage12V24V230V235V /235V /235V /235V /235V /----Nominalcurrent16A16A16

Página 50 - 800A

RedlineD.6Comfort functionsABCDEFGXFunctionContactors are electromechanicallycontrolled switches used to controlsingle or multi-phase (high) powerload

Página 51

RedlineD.7ContaxABCDEFGXNominalcurrent20A20A20A20A20A20A20A20A20A24A24A24A24A24A24A24A24A24A24A24A40A40A40A40A40A40A40A40A40A40A63A63A63A63A20A24A24A4

Página 52 - GE imagination at work

RedlineD.8Comfort functionsABCDEFGXRelaysStandards / MarkingEN 60947-4-1Contax RFunctionRelays are electromechanically controlled switches used to con

Comentários a estes Manuais

Sem comentários