AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes
PN 613-001136 Rev. B 12 Allied Telesis Inc.
Verify that you correctly entered the names of the image files in the TFTP Image Download
Configuration Menu. The filenames must include the “.img” extension.
If the upgrade process stops or freezes while the management card is transferring an image file to a line
card or while a line card is writing an image file to flash memory, try performing the following procedure:
1. If no further status messages appear after five minutes, try pressing Return. If the management card is
unresponsive, reset the card using the CPU Reset button on the front faceplate. Or, remove the card
from the chassis and then reinstall it.
2. Wait one minute for the management card to initialize its management software and then start a new
local management session.
3. From the Main Menu select Module Status and Configuration. An example of the menu is shown on
page 6.
4. Examine the Ver column to determine which, if any, of the cards were successfully updated. For those
line cards that were not updated, repeat Phase 6 and upgrade the cards individually using the Single
Local Line Card Image option or, for remote line cards, the Single Remote Line Card Image option.
5. If you are repeatedly unable to upgrade a particular line card, try installing it in a different slot in the
chassis and repeat Phase 6 for that card.
Upgrading Versions Earlier than Version 3.0.0
If the AT-S73 Management Software on any of the AT-CM2 and AT-CM70S Line Cards is earlier than
Version 3.0.0, you’ll have to install all of the previous releases in sequence up to Version 3.0.0 before
installing Version 4.0.1. For example, if a line card has Version 1.5 of the AT-S73 Management Software,
you have to install Versions 1.6, 1.7, and 2.0.2, 3.0.0, and 4.0.1. All of the releases are available from the
Allied Telesis web site.
Note:
Skipping a release may damage a line card.
To determine the version numbers of the management software programs on the line cards:
If the chassis has the AT-CV5M01 Management Card, start a local or remote management session
and from the Main Menu select Administration -> Diagnostics -> Line Card Image Version. In the
Line Card Module Software Image Version window, examine the version numbers of the management
software programs on the cards. If the version number for a line card is blank, the line card and the
management card have different versions of the AT-S70 and AT-S73 Management Software.
There may be a label with the software version number on the line card’s shipping box.
There may be a label on one of the chips on the line card.
Review the following information:
If you are unable to ascertain the version number of the AT-S73 Management Software on an AT-CM2
or AT-CM70S Line Card, your only recourse is to install all of the previous versions in sequence,
starting with Version 1.4.0.
Allied Telesis recommends using the AT-CV5M01 Management Card to upgrade the line cards to
Version 2.0.2. If you do not have that card, you can either contact your Allied Telesis sales
representative for assistance or try using the AT-CV5M02 Management Card, though the results may
not be predictable.
Version 1.7.0 has a new bootloader. When installing that version on a media converter line card, install
the bootloader first and then the management software.