Vista de página 5
ADCMP341/ADCMP343 Data Sheet
Rev. A | Page 6 of 12
TYPICAL PERFORMANCE CHARACTERISTICS
0
10
20
30
40
50
PERCENT OF UNITS (%)
RISING INPUT THRESHOLD VOLTAGE (mV)
60
394 395 396 397 398 399 400 401 402 403 404 405 406
06500-005
V
DD
= 5V
T
A
= 25°C
Figure 6. Distribution of Rising Input Threshold Voltage
395
RISING INPUT THRESHOLD VOLTAGE (mV)
SUPPLY VOLTAGE (V)
401
400
399
398
397
396
1.7 5.75.24.74.23.73.22.72.2
T
A
= –40°C
T
A
= +25°C
T
A
= +85°C
T
A
= +125°C
06500-007
Figure 7. Rising Input Threshold Voltage vs. Supply Voltage
10
4
5.2
SUPPLY CURRENT (µA)
SUPPLY VOLTAGE (V)
9
8
7
6
5
1.7 2.2 2.7 3.2 3.7 4.2 4.7
T
A
= +125°C
T
A
= +85°C
T
A
= +25°C
T
A
= –40°C
06500-008
NO LOAD CURRENT
Figure 8. Quiescent Supply Current vs. Supply Voltage
396
RISING INPUT THRESHOLD VOLTAGE (mV)
TEMPERATUREC)
404
402
400
398
–40 –20 1200 20406080100
4
3
2
1
0
6500-006
FOUR TYPICAL PARTS
V
DD
= 5V
Figure 9. Rising Input Threshold Voltage vs. Temperature
–5
THRESHOLD SHIFT (mV)
SUPPLY VOLTAGE (V)
1
1.5 2.52.42.32.22.12.01.91.81.71.6
06500-009
T
A
= +125°C
T
A
= +85°C
T
A
= +25°C
T
A
= –40°C
0
–1
–2
–3
–4
Figure 10. Minimum Supply Voltage
50
0
1.5
SUPPLY CURRENT (µA)
SUPPLY VOLTAGE (V)
40
30
20
10
00.51.0
06500-010
T
A
= +125°C
T
A
= +85°C
T
A
= +25°C
T
A
= –40°C
Figure 11. Start-Up Supply Current
Vista de página 5